Performance of absorption coefficient measurements for the in situ determination of chlorophyll-a and total suspended matter


Contact
Karen.Helen.Wiltshire [ at ] awi.de

Abstract

The concentrations of chlorophyll-. a ([chl-. a]) and total suspended matter ([TSM]) are important parameters in biological oceanography. [Chl-. a] is a commonly used proxy for estimating phytoplankton biomass while [TSM] also includes detrital material and mineral particles and thus influences light attenuation and photosynthetic activity in the water column.For characterizing the distribution (patchiness) of both parameters adequately over a longer time period, fast and effective measurement methods are required that can also be applied in situ or continuously. Thus, alternatively to direct determination of [chl-. a] and [TSM], optical proxy values are often measured. The PSICAM is an integrating cavity approach for measuring absorption coefficients of water constituents with high precision which can be used also continuously (flow-through-PSICAM). In this study, the performance of these absorption measurements for [chl-. a] and [TSM] determination was evaluated and compared with the performance of traditional approaches using chl-. a fluorescence and turbidity measurements.Data were collected in the German Bight (North Sea) in 2010 and 2011. For [chl-a], fluorescence measurements are compared with pigment absorption coefficient values at a wavelength of 676nm (aΦ 676nm), while the [TSM]-proxies were turbidity and particle absorption at 700nm (ap 700nm). As reference data, HPLC-determined [chl-a] and gravimetrically determined [TSM] were used.Our results showed linear relationships between [chl-a] and fluorescence or aΦ 676nm, respectively. Coefficients of determination (R2) were in a range of 0.71 to 0.88, with the higher values related to the absorption measurements. Furthermore, it was demonstrated that fluorescence underestimates [chl-a] depending on ambient photosynthetically active radiation (PAR). Linear relationships were also observed between [TSM] and its optical proxies with R2 values between 0.93 and 0.98. Turbidity measurements appeared to be influenced to a certain extent by the physical properties of the suspended material, resulting in a slightly higher variability than the ap 700nm measurements.Absorption measurements turned out to be promising optical proxies for determining [TSM] and [chl-. a] due to their lower variability compared with the other proxies. This improved accuracy could be already partially achieved also for continuous measurements. Moreover, a combination of the different optical methods has the potential to provide additional information besides concentration, such as the source of TSM in the water or physiological condition of the phytoplankton. © 2014 Elsevier B.V.



Item Type
Article
Authors
Divisions
Primary Division
Programs
Primary Topic
Research Networks
Publication Status
Published
Eprint ID
44922
DOI https://www.doi.org/10.1016/j.jembe.2014.01.011

Cite as
Wollschläger, J. , Röttgers, R. , Petersen, W. and Wiltshire, K. H. (2014): Performance of absorption coefficient measurements for the in situ determination of chlorophyll-a and total suspended matter , Journal of Experimental Marine Biology and Ecology, 453 , pp. 138-147 . doi: https://www.doi.org/10.1016/j.jembe.2014.01.011


Share


Citation

Geographical region

Research Platforms
N/A

Campaigns
N/A


Actions
Edit Item Edit Item